Digital Multimeter Type TBM811 (TED14S)

R3,594.73

The TBM811 offers excellent quality and service, at a very reasonable price!

Features include a large 3½-digit readout, protection to 1000V, splash proof, transient protected to 6.5kV, CATIII 600V protected, an RS232 Interface, holster and LIFETIME warranty!

Software is available separately as Order Code TED16S.

The unit is fully auto-ranging and ranges include DCV, ACV, DC I, AC I, Resistance, Capacitance and Frequency.

General Specifications

Display: 3-4/5 digits 5000 counts LCD display
Update Rate: Digital Data 5 per second nominal
52 Segments Bar-graph 60 per second nominal
AC Sensing: Average sensing
Operating Temperature: 0°C to 45°C
Relative Humidity: Maximum relative humidity 80% for
temperature up to 31°C decreasing linearly to 50%
relative humidity at 45°C
Storage Temperature: -20°C to 60°C, 80% R.H. (with
battery removed)
Pollution degree: 2
Altitude: Operating below 2000m
Temperature Coefficient: Nominal 0.15 (specified
accuracy)/°C @(O°C -- 18°C or 28°C -- 45°C), or
otherwise specified
Power Supply: Single standard 9V battery NEDA1604,
JIS006P or IEC6F22
Power Consumption: 2.6 mA typical
Low Battery: Below approx.7V
APO Timing: Idle for 17 minutes
Dimension: L186mm x W87mm x H35.5mm; L198mm x W97mm x H55mm with holster
Weight: 340 gm; 430 gm with holster
Accessories: Test leads (pair); Holster; Battery
(installed); User''s manual

Technical Specifications

DC VOLTAGE
RangeAccuracy
50.00 mV0.12% + 2d
500.0 mV0.06% + 2d
5.000V, 50.00V, 500.0V,1000V0.08% + 2d

NMRR :>60dB @ 50/60Hz
CMRR :>120dB @ DC, 50/60Hz, Rs=1kOhm
Input Impedance: 10MOhm, 16pF nominal
(44pF nominal for 50mV & 500mV ranges)

AC VOLTAGE(50Hz--60Hz)
RangeAccuracy
50.00mV, 500.0mV, 5.000V, 50.00V, 500.0V, 1000V0.5% + 3d
(40Hz--500Hz)
50.00mV, 500.0mV0.8% + 3d
5.000V, 50.00V, 500.0V1.0% + 4d
1000V1.2% + 4d
Up to 20kHz
50.00mV, 500.0mV0.5dB*
5.000V, 50.00V, 500.0V3dB*
1000VUnspec''d

*Specified from 30% to 100% of range
CMRR :>60dB @ DC to 60Hz, Rs=1kOhm
Input Impedance : 10MOhm, 16pF nominal
(44pF nominal for 50mV & 500mV ranges)

DC CURRENT
RangeAccuracyBurden Voltage
500.0µA0.2%+4d0.15mV/µA
5000µA0.2%+4d0.15mV/µA
50.00mA0.2%+4d3.3mV/mA
500.0mA0.2%+4d3.3mV/mA
5.000A0.2%+4d0.03V/A
10.00A*0.2%+4d0.03V/A

*10A continuous, 20A for 30 seconds max with 5 minutes cool down interval.


AC CURRENT50Hz--60Hz
RangeAccuracyBurden Voltage
500.0µA0.6%+3d0.15mV/µA
5000µA0.6%+3d0.15mV/µA
50.00mA0.6%+3d3.3mV/mA
500.0mA1.0% + 3d3.3mV/mA
5.000A0.6% + 3d0.03V/A
5.00A0.6% + 3d0.03V/A
10.00A*0.6%+3d0.03V/A
40Hz--1kHz
500.0µA0.8%+4d0.15mV/µA
5000µA0.8%+4d0.15mV/µA
50.00mA0.8%+4d3.3mV/mA
500.0mA1.0%+4d3.3mV/mA
10.00A*0.8%+4d0.03V/A

*10A continuous, 20A for 30 seconds max with 5 minutes cool down interval

RESISTANCE
RangeAccuracy
50.00Ohm0.2% + 6d
500.0Ohm0.1% + 3d
5.000kOhm, 50.00kOhm, 500.0kOhm0.1% + 2d
5.000MOhm0.4% + 3d
50.00MOhm1.5% + 5d

Open Circuit Voltage : < 1.3VDC
(<3VDC for 50Ohm & 500Ohm ranges)

FREQUENCY
FunctionSensitivity (Sine RMS)Range
mV300mV6Hz - 125kHz
5V2V6Hz - 125kHz
50V20V6Hz - 20kHz
500V80V6Hz - 1kHz
1000V300V6Hz - 1kHz
Ohm, Cx, diode300mV6Hz - 125kHz
µA, mA, A10% F.S.6Hz - 125kHz

Accuracy: 0.01% + 2d

CAPACITANCE
RangeAccuracy*
50.00nF0.8% + 3d
500.0nF0.8% + 3d
5.000µF1.0% + 3d
50.00µF2.0% + 3d
500.0µF3.5% + 5d
9999µF5.0% + 5d

*Accuracies with film capacitor or better


DIODE TESTER
RangeAccuracy CurrentTest Circuit (Typical)Open Voltage
2.000V DC1%+1d0.8mA<3.5


AUDIBLE CONTINUITY TEST
Audible thresholdbetween 20Ohm and 200Ohm

Fast response time < 100µs